GE FANUC Analog I/O Module TGT-AI0V-8-0-BC Industrial Control Precision at Its Core
Operating Temperature Range:-20"C to +60"C Input Voltage Range:10 to 30 VDC Output Current Range:0 to 20 mA Number of Channels:8 Analog Input, 0 Analog Output Communication Protocol:MODBUS RTU Power Supply:DC 24V Dimensions (WxHxD):96 x 96 x 34 mm Weight:0.2 kg Enclosure Type:IP20 Operating Humidity Range:5 to 95% non-condensing
The GE FANUC TGT-AI0V-8-0-BC Analog I/O Module is a robust solution for real-time data acquisition and control in demanding industrial settings. Its compact design ensures seamless integration into various control systems without compromising functionality or performance. Featuring a wide operating temperature range from -20"C to +60"C, this module is engineered to withstand harsh environmental conditions, making it ideal for applications in manufacturing, automation, and process control industries.
Equipped with high-precision analog input channels, the TGT-AI0V-8-0-BC offers exceptional measurement accuracy, ensuring reliable data collection essential for critical operations.
Its compatibility with MODBUS RTU protocol facilitates easy communication with a wide array of industrial devices. With a low-profile footprint of 96 x 96 x 34 mm and a lightweight design of just 0.2 kg, the module is easy to install and can be conveniently mounted on control panels or within cabinets. The IP20 enclosure provides adequate protection against dust and light splashes, enhancing its durability in industrial environments. To ensure smooth operation and maintenance, the GE FANUC Analog I/O Module comes with comprehensive documentation and support resources, including detailed user manuals and access to technical experts.
This commitment to customer service ensures that users can leverage the full capabilities of the module without any hindrance. Engineered for industrial precision, the GE FANUC TGT-AI0V-8-0-BC Analog I/O Module offers seamless integration and enhanced data acquisition in demanding automation environments.
Comprehensive quality inspection process
Raw material quality testing: Before production, all raw materials are subjected to strict quality testing. For electronic components, such as chips, resistors, capacitors, operational amplifiers, etc., their electrical performance, parameter accuracy, etc. are precisely tested to ensure that they meet high quality standards. For example, A/D and D/A converter chips are thoroughly tested for accuracy, conversion speed, stability, etc. Resistors and capacitors are strictly screened for capacitance, resistance accuracy, and withstand voltage value.
The raw materials of PCB boards, such as insulation performance of copper-clad boards and thickness of copper foils, are tested to prevent the overall performance of the module from being affected by the quality of raw materials. At the same time, the mechanical strength, fire resistance and anti-electromagnetic interference performance of the module shell materials are tested to ensure that they comply with relevant safety standards and industrial application requirements.