
GE IC697MEM717C Memory Module for Industrial Automation Systems
Module Type:Memory Module Manufacturer:GE Model Number:IC697MEM717C Compatibility:GE Series 90-30 PLCs Memory Capacity:1 MB Data Transfer Rate:Up to 5 MHz Voltage Rating:5 VDC Operating Temperature Range:-40"C to 85"C Physical Dimensions:3.9 x 2.4 x 0.6 inches Weight:0.1 lbs Certifications:CE, UL The GE IC697MEM717C memory module is engineered to deliver exceptional performance in industrial automation environments. Designed for reliability and durability, this memory module is capable of handling extensive data storage and retrieval needs, making it ideal for critical applications.
With its robust design and wide operating temperature range, the GE IC697MEM717C ensures stable and consistent performance under harsh conditions. Compatible with various GE IC69 PLC series, this memory module offers seamless integration and enhanced system efficiency.
Trust in the quality and performance of the GE IC697MEM717C to elevate your industrial automation solutions. The GE IC697MEM717C is a high-performance memory module designed for industrial automation systems, enhancing data storage capabilities and operational efficiency in various industrial environments.
Performance Features
1.Mass storage: The GE IC697MEM717C memory module has a high-capacity storage capacity of up to [X] MB, which is able to meet the needs of industrial automation systems for large amounts of data storage. In the industrial production process, all kinds of sensors collect massive production data in real time, such as equipment operation status, process parameters, product quality inspection data, etc., which need to be stored timely and accurately for subsequent analysis and processing. For example, in the automated production line of automobile manufacturing, the production process of each car is accompanied by a large amount of assembly data, quality inspection data, etc. The IC697MEM717C can easily store these data to provide a data base for the traceability of the production process, quality control and improvement of production efficiency. Its high-capacity storage enables industrial automation systems to save long-time historical data, which helps enterprises to analyse production trends, predict failures and optimise production processes, thus improving their competitiveness.
2.High-speed data read/write: The memory module has excellent high-speed data read/write performance, with data read speeds of up to [X] MB/s and write speeds of up to [X] MB/s. In industrial automation systems, real-time is the key, and fast data read/write capability can ensure that the system responds to various changes in the production process in a timely manner. For example, in the power scheduling system of smart grid, it is necessary to monitor the voltage, current, power and other parameters of the grid in real time, and quickly adjust the power distribution strategy according to these parameters.The high-speed data read/write performance of IC697MEM717C enables the system to quickly read the sensor data and quickly write the control commands into the execution equipment, so as to achieve accurate and real-time control of the grid, and to guarantee the stability and reliability of the power supply. stability and reliability of power supply. In the automated production line, the high-speed data read/write capability can ensure that the production equipment obtains production instructions in a timely manner, provides rapid feedback on the production status, improves production efficiency, and reduces production downtime.
Technical specifications
Storage capacity: [X] MB, to meet the needs of industrial automation systems for large amounts of data storage.
Data reading and writing speed: read speed is [X] MB/s, write speed is [X] MB/s, to ensure the fast storage and reading of data, to meet the system requirements for real-time.
Operating temperature range: -40 ℃ to 85 ℃, can adapt to the harsh industrial environment temperature changes, to ensure that the normal work in different temperature conditions.
Operating humidity range: 5% - 95% RH (non-condensing), maintaining stable performance in humid industrial environments without affecting data storage and transmission.
Anti-vibration and shock resistance: good anti-vibration and shock resistance, able to withstand the vibration and shock generated by the operation of industrial equipment to ensure the reliability of data storage.
Interface type: Adopting the standard [interface type] interface, it is convenient to connect with other devices in the industrial automation system to achieve rapid data transmission and interaction.
Data protection technology: Built-in data protection and error correction technology such as Parity Check and CRC to ensure data integrity and accuracy; supports power-down data protection function.
